Estimating plasma glucose from interstitial glucose: the issue of calibration algorithms in commercial continuous glucose monitoring devices P Rossetti, J Bondia, J Vehí, CG Fanelli Sensors 10 (12), 10936-10952, 2010 | 146 | 2010 |
Comprehensive pharmacokinetic model of insulin glargine and other insulin formulations C Tarin, E Teufel, J Picó, J Bondia, HJ Pfleiderer IEEE Transactions on Biomedical Engineering 52 (12), 1994-2005, 2005 | 102 | 2005 |
Enhancing automatic closed-loop glucose control in type 1 diabetes with an adaptive meal bolus calculator–in silico evaluation under intra-day variability P Herrero, J Bondia, O Adewuyi, P Pesl, M El-Sharkawy, M Reddy, ... Computer methods and programs in biomedicine 146, 125-131, 2017 | 89 | 2017 |
Safety auxiliary feedback element for the artificial pancreas in type 1 diabetes A Revert, F Garelli, J Picó, H De Battista, P Rossetti, J Vehí, J Bondia IEEE transactions on Biomedical Engineering 60 (8), 2113-2122, 2013 | 83 | 2013 |
Unannounced meals in the artificial pancreas: detection using continuous glucose monitoring CM Ramkissoon, P Herrero, J Bondia, J Vehi Sensors 18 (3), 884, 2018 | 78 | 2018 |
Insulin estimation and prediction: A review of the estimation and prediction of subcutaneous insulin pharmacokinetics in closed-loop glucose control J Bondia, S Romero-Vivo, B Ricarte, JL Diez IEEE Control Systems Magazine 38 (1), 47-66, 2018 | 65 | 2018 |
Real-time glucose estimation algorithm for continuous glucose monitoring using autoregressive models Y Leal, W Garcia-Gabin, J Bondia, E Esteve, W Ricart, ... Journal of diabetes science and technology 4 (2), 391-403, 2010 | 65 | 2010 |
Accuracy of continuous glucose monitoring before, during, and after aerobic and anaerobic exercise in patients with type 1 diabetes mellitus L Biagi, A Bertachi, C Quirós, M Giménez, I Conget, J Bondia, J Vehí Biosensors 8 (1), 22, 2018 | 60 | 2018 |
Automated blood glucose control in type 1 diabetes: A review of progress and challenges A Bertachi, CM Ramkissoon, J Bondia, J Vehí Endocrinología, Diabetes y Nutrición (English ed.) 65 (3), 172-181, 2018 | 58 | 2018 |
Real-time continuous glucose monitoring in an intensive care unit: better accuracy in patients with septic shock C Lorencio, Y Leal, A Bonet, J Bondia, CC Palerm, A Tache, JM Sirvent, ... Diabetes technology & therapeutics 14 (7), 568-575, 2012 | 58 | 2012 |
Method for automatic adjustment of an insulin bolus calculator: in silico robustness evaluation under intra-day variability P Herrero, P Pesl, J Bondia, M Reddy, N Oliver, P Georgiou, C Toumazou Computer methods and programs in biomedicine 119 (1), 1-8, 2015 | 55 | 2015 |
A new blood glucose control scheme for unannounced exercise in type 1 diabetic subjects A Beneyto, A Bertachi, J Bondia, J Vehi IEEE Transactions on Control Systems Technology 28 (2), 593-600, 2018 | 53 | 2018 |
Closed-loop control of postprandial glycemia using an insulin-on-board limitation through continuous action on glucose target P Rossetti, C Quiros, V Moscardo, A Comas, M Giménez, ... Diabetes technology & therapeutics 19 (6), 355-362, 2017 | 53 | 2017 |
Analysis of linear systems with fuzzy parametric uncertainty J Bondia, J Picó Fuzzy sets and systems 135 (1), 81-121, 2003 | 52 | 2003 |
Seasonal local models for glucose prediction in type 1 diabetes E Montaser, JL Díez, P Rossetti, M Rashid, A Cinar, J Bondia IEEE journal of biomedical and health informatics 24 (7), 2064-2072, 2019 | 47 | 2019 |
Coordinated basal—bolus infusion for tighter postprandial glucose control in insulin pump therapy J Bondia, E Dassau, H Zisser, R Calm, J Vehí, L Jovanovič, FJ Doyle III Journal of diabetes science and technology 3 (1), 89-97, 2009 | 42 | 2009 |
El páncreas artificial: control automático de infusión de insulina en diabetes mellitus tipo 1 J Bondia, J Vehí, CC Palerm, P Herrero Revista Iberoamericana de Automática e Informática Industrial RIAI 7 (2), 5-20, 2010 | 41 | 2010 |
Artificial pancreas system with unannounced meals based on a disturbance observer and feedforward compensation R Sanz, P García, JL Díez, J Bondia IEEE Transactions on Control Systems Technology 29 (1), 454-460, 2020 | 39 | 2020 |
Robust sliding mode closed-loop glucose control with meal compensation in type 1 diabetes mellitus W Garcia-Gabin, J Vehí, J Bondia, C Tarín, R Calm IFAC Proceedings Volumes 41 (2), 4240-4245, 2008 | 37 | 2008 |
Real-time estimation of plasma insulin concentration from continuous glucose monitor measurements D De Pereda, S Romero-Vivo, B Ricarte, P Rossetti, FJ Ampudia-Blasco, ... Computer methods in biomechanics and biomedical engineering 19 (9), 934-942, 2016 | 36 | 2016 |