Chemical and pH sensors based on the swelling behavior of hydrogels G Gerlach, M Guenther, J Sorber, G Suchaneck, KF Arndt, A Richter Sensors and Actuators B: Chemical 111, 555-561, 2005 | 314 | 2005 |
Review of micromachined thermopiles for infrared detection A Graf, M Arndt, M Sauer, G Gerlach Measurement Science and Technology 18 (7), R59-R75, 2007 | 277 | 2007 |
Thermal infrared sensors: theory, optimisation and practice H Budzier, G Gerlach John Wiley & Sons, 2011 | 276 | 2011 |
Hydrogel sensors and actuators: engineering and technology G Gerlach, KF Arndt Springer Science & Business Media, 2009 | 244 | 2009 |
The measurement of dissolved and gaseous carbon dioxide concentration J Zosel, W Oelßner, M Decker, G Gerlach, U Guth Measurement Science and Technology 22 (7), 072001, 2011 | 161 | 2011 |
Calibration of uncooled thermal infrared cameras H Budzier, G Gerlach Journal of Sensors and Sensor Systems 4 (1), 187-197, 2015 | 122 | 2015 |
A survey on piezoelectric ceramics for generator applications T Rödig, A Schönecker, G Gerlach Journal of the American Ceramic Society 93 (4), 901-912, 2010 | 115 | 2010 |
Introduction to microsystem technology: a guide for students G Gerlach, W Dotzel John Wiley & Sons, 2008 | 102 | 2008 |
Chemical sensors based on multiresponsive block copolymer hydrogels M Günther, D Kuckling, C Corten, G Gerlach, J Sorber, G Suchaneck, ... Sensors and Actuators B: Chemical 126 (1), 97-106, 2007 | 101 | 2007 |
Application of sensitive hydrogels in chemical and pH sensors G Gerlach, M Guenther, G Suchaneck, J Sorber, KF Arndt, A Richter Macromolecular Symposia 210 (1), 403-410, 2004 | 100 | 2004 |
Hydrogel-based piezoresistive pH sensors: Design, simulation and output characteristics QT Trinh, G Gerlach, J Sorber, KF Arndt Sensors and Actuators B: Chemical 117 (1), 17-26, 2006 | 95 | 2006 |
A piezoresistive humidity sensor G Gerlach, K Sager Sensors and Actuators A: Physical 43 (1-3), 181-184, 1994 | 87 | 1994 |
Hydrogel-based piezoresistive pH sensors: investigations using FT-IR attenuated total reflection spectroscopic imaging J Sorber, G Steiner, V Schulz, M Guenther, G Gerlach, R Salzer, KF Arndt Analytical Chemistry 80 (8), 2957-2962, 2008 | 81 | 2008 |
Characterization of ion-beam modified polyimide layers K Sahre, KJ Eichhorn, F Simon, D Pleul, A Janke, G Gerlach Surface and Coatings Technology 139 (2-3), 257-264, 2001 | 75 | 2001 |
Humidity-dependent mechanical properties of polyimide films and their use for IC-compatible humidity sensors K Sager, A Schroth, A Nakladal, G Gerlach Sensors and actuators A: Physical 53 (1-3), 330-334, 1996 | 75 | 1996 |
Design studies on piezoresistive humidity sensors R Buchhold, A Nakladal, G Gerlach, P Neumann Sensors and Actuators B: Chemical 53 (1-2), 1-7, 1998 | 70 | 1998 |
Ion-beam induced chemical and structural modification in polymers M Guenther, G Gerlach, G Suchaneck, K Sahre, KJ Eichhorn, B Wolf, ... Surface and Coatings Technology 158, 108-113, 2002 | 65 | 2002 |
Scanning force microscopy investigation of the Pb (Zr0. 25Ti0. 75) O3/Pt interface XM Lu, F Schlaphof, S Grafström, C Loppacher, LM Eng, G Suchaneck, ... Applied physics letters 81 (17), 3215-3217, 2002 | 61 | 2002 |
Enzyme-functionalized piezoresistive hydrogel biosensors for the detection of urea J Erfkamp, M Guenther, G Gerlach Sensors 19 (13), 2858, 2019 | 58 | 2019 |
Fabrication of a 3D differential-capacitive acceleration sensor by UV-LIGA W Qu, C Wenzel, G Gerlach Sensors and Actuators A: Physical 77 (1), 14-20, 1999 | 58 | 1999 |